CLDCompressi aeris Frigidus dryer
Secundum principium refrigerationis et dehumidificationis, refrigeratio aeris siccioris compressi commutat calidum et humidum compressum aerem per evaporatorem, humorem gaseum aeris compressi in aquam liquidam condensat, eamque per gasi- liquam separatorem exhaurit.
Technical Indicatores
A: Aeris refrigeratum dryer
Facultas aeris tractandi: 1-500n ㎥ / min
Pressura operans: 0.6-1.0mpa (1.0-3.0mpa producta praeberi potest secundum usorum requisita)
Rated aeris inlet temperatura: normale temperaturae genus: ≤ 45 ℃ (min5 ℃)
Altum temperatum genus: ≤ 85 ℃ (min5 ℃)
Modus refrigerationis: aeris refrigerationem
Ros producti gas punctum: ≤ - 23 (punctum atmosphaericum)
Pressura guttae diverticuli et exitus aeris: ≤ o, 02mpa
Modus institutionis: sub tectis institutionem sine fundamento
Temperatus ambiens: ≤ 42 ℃ (min0 ℃)
B: aqua frigida dryer
Facultas aeris tractandi: 1-500n ㎥ / min
Pressura operans: 0.6-1.0mpa (1.0-3.0mpa producta praeberi potest secundum usorum requisita)
Rated aeris inlet temperatura: normale temperaturae genus: normale temperatus typus: ≤ 45 ℃ (min5 ℃)
Altum temperatum genus: ≤ 85 ℃ (min5 ℃)
Modus refrigerandi: aqua refrigeratio
Aquae diverticulum temperatura aquae frigidae: ≤ 32 ℃ (min5 ℃)
Aquae refrigerationis pressura inlet: 0.2-0.4mpa
Ros producti gas punctum: ≤ - 23 (punctum atmosphaericum)
Pressura guttae diverticuli et exitus aeris: ≤ o, 02mpa
Modus institutionis: sub tectis institutionem sine fundamento
Temperatus ambiens: ≤ 45 ℃ (min0 ℃)
Technical Features
Adhibet internationalem celeberrimam refrigerationem compressorem cum operatione stabili, voce humilis, consummatio energiae, salus et commendatio.
Danfoss est principale refrigerationis accessorium machinae huius.
Ad vitandam secundariam pollutionem aeris compressi, in processu productionis, pars aeris effluendo plastica tractatur;unicum consilium separationis gas-liquidae magis blowdown profundiorem reddit.
Parva structura, nulla fundatio institutionis.
Progressio programmabilis moderatio, munus digitale monstrare in aspectu.
Usura electronic blowdown, non facile intercludere, humilis industria consummatio.
instrui potest cum RS485/ RS232 et interface ad intermedium remotum communicationis, vigilantia centralised et compressoris aeri compaginis.
Habet varias culpae terrores et functiones processus.
Nota:computatorium genus et commune genus frigidum dryer ab usoribus sumi potest.
Normalis temperatus aer refrigeratum frigus dryer
Exemplar / parametri nomen | CLD-1F | CLD-3F | CLD-6F | CLD-10F | CLD-12F | CLD-15F | CLD-20F | CLD-30F | CLD-40F | CLD-60F | |
Aeris fluxus N㎥/min
| 1.6 | 3.8 | 6.5 | 11.7 | 13 | 17 | 23 | 34 | 45 | 65 | |
Potestas Supple | 1Ph/220V/50Hz | 3Ph/380V/50Hz | |||||||||
Cogo power(KW) | 0.39 | 0.915 | 1.57 | 1.94 | 2.57 | 2.94 | 4.4 | 5.5 | 7.35 | 11.03 | |
Fan power(W) | 60 | 90 | 120 | 180 | 240 | 360 | 360 | 750 | 750 | 1140 | |
Diameter limbi et exitus DN(mm) | 25 | 40 | 40 | 50 | 50 | 82 | 82 | 100 | 100 | 125 | |
Terminus dimensionmm) | Longitudo | 760 | 760 | 940 | 1100 | 1300 | 1400 | 1550 | 1850 | 1850 | MMCC |
Latitudo | 430 | 430 | 550 | 600 | 620 | 650 | 800 | 800 | 800 | 950 | |
Altitudo | 715 | 715 | 800 | 950 | 980 | 950 | 1200 | 1300 | 1300 | 1600 | |
Net pondus armorum (kg) | 79 | 84 | 173.5 | 260 | 275 | 380 | 460 | 650 | 750 | 1350 |
Princeps temperatus aer refrigeratum dryer
Exemplar / parametri nomen | CLD-1HF | CLD-3HF | CLD-6HF | CLD-10HF | CLD-12HF | CLD-15HF | CLD-20HF | CLD-30HF | CLD-40HF | CLD-60HF | |
Aeris fluxus N㎥/min
| 1.6 | 3.8 | 6.5 | 11.7 | 13 | 17 | 23 | 34 | 40 | 60 | |
Potestas Supple | 1Ph/220V/50Hz | 3Ph/380V/50Hz | |||||||||
Cogo power(KW) | 0.39 | 0.915 | 1.57 | 1.94 | 2.57 | 2.94 | 4.4 | 5.5 | 4.5 | 7.4 | |
Fan power(W) | 160 | 170 | 210 | 300 | 420 | 600 | 600 | 1250 | 900 | 1320 | |
Diameter limbi et exitus DN(mm) | 25 | 40 | 40 | 50 | 50 | 80 | 80 | 100 | 100 | 125 | |
Terminus dimensionmm) | Longitudo | 760 | 760 | 900 | 1100 | 1300 | 1550 | 1550 | 1850 | 1850 | 2100 |
Latitudo | 430 | 430 | 550 | 600 | 620 | 650 | 800 | 800 | 800 | 900 | |
Altitudo | 950 | 950 | 1070 | 1320 | 1275 | 1430 | 1580 | 200 | 2050 | 2250 | |
Net pondus armorum (kg) | 94.5 | 103 | 197 | 360 | 380 | 470 | 580 | 800 | 1160 | 1500 |
Normalis temperatus aqua refrigeratum frigus dryer
Exemplar / parametri nomen | CLD-6W | CLD-10W | CLD-12W | CLD-15W | CLD-20W | CLD-30W | CLD-40W | CLD-60W | CLD-80W | CLD-100W | CLD-120W | CLD-150W | CLD-200W | CLD-300W | |
Aeris fluxus N㎥/min
| 6.5 | 10 | 13 | 17 | 23 | 34 | 45 | 65 | 86 | 110 | 120 | 168 | 220 | 330 | |
Potestas Supple | 1Ph/220V/50Hz | 3Ph/380V/50Hz | |||||||||||||
Cogo power(KW) | 1.57 | 1.94 | 2.57 | 2.94 | 4.4 | 5.5 | 7.35 | 11.03 | 14.7 | 22.05 | 14 | 30 | 36 | 55 | |
Aquae refrigerationem circulation(N㎥/min) | 1 | 1.6 | 1.8 | 2.4 | 3.2 | 4.8 | 6.3 | 9.5 | 12.6 | 15.8 | 18.9 | 23.6 | 32 | 47.2 | |
Diameter aeris fistulae DN(mm) | 40 | 50 | 50 | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 150 | 200 | 200 | 300 | |
Diameter aqua frigida fistula | G1/2" | G1/2" | G1/2" | G3/4" | G3/4" | G1½" | G1½" | G1½" | G2" | G2" | G2" | G2" | G2" | DN80 | |
Terminus dimensionmm) | Longitudo | 940 | 1100 | 1300 | 1400 | 1550 | 1850 | 1850 | 2250 | 2400 | 2500 | 2600 | 3100 | 3400 | 4500 |
Latitudo | 550 | 600 | 520 | 650 | 800 | 800 | 800 | 1000 | 1200 | 1400 | 1450 | 1750 | 1450 | 1900 | |
Altitudo | 800 | 980 | 980 | 950 | 1200 | 1300 | 1500 | 1850 | 2020 | 1650 | 2100 | 2520 | 2400 | 2595 | |
Net pondus armorum (kg) | 173.5 | 260 | 275 | 380 | 460 | 650 | 750 | 1350 | 2000 | 2300 | MMCC | 3000 | 3800 | 5800 |
Caliditas aquae refrigeratae frigidae dryer
Exemplar / parametri nomen | CLD-6HW | CLD-10HW | CLD-12HW | CLD-15HW | CLD-20HW | CLD-30HW | CLD-40HW | CLD-60HW | CLD-80HW | CLD-100HW | CLD-120HW | CLD-150HW | CLD-200HW | CLD-300HW | |
Aeris fluxus N㎥/min
| 6 | 11.7 | 13 | 17 | 23 | 34 | 45 | 65 | 86 | 110 | 120 | 150 | 200 | 300 | |
Potestas Supple | 1Ph/220V/50Hz | 3Ph/380V/50Hz | |||||||||||||
Cogo power(KW) | 1.25 | 1.94 | 2.57 | 2.94 | 4.4 | 5.5 | 7.35 | 11.03 | 11.7 | 22.05 | 14 | 18 | 23 | 36 | |
Aquae refrigerationem circulation(N㎥/min) | 1.9 | 3 | 3.5 | 4.7 | 6 | 9.5 | 12 | 18.9 | 24.5 | 30 | 34 | 46 | 60 | 91 | |
Diameter aeris fistulae DN(mm) | 40 | 50 | 50 | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 150 | 200 | 200 | 250 | |
Diameter aqua frigida fistula | G1/2" | G1/2" | G1/2" | G3/4" | G3/4" | G1½" | G1½" | G1½" | G2" | G2" | G2" | G2" | G3" | G3" | |
Terminus dimensionmm) | Longitudo | 950 | 1100 | 1300 | 1550 | 1550 | 1850 | 1850 | 2780 | 2800 | 3150 | 2860 | 2980 | 3100 | 3800 |
Latitudo | 650 | 600 | 620 | 650 | 800 | 880 | 800 | 1150 | 1555 | 1555 | 1450 | 1580 | 1900 | 2800 | |
Altitudo | 1000 | 1320 | 1275 | 1430 | 1580 | 1630 | 1630 | 2045 | 1930 | 1930 | 2400 | 2410 | 2750 | 3100 | |
Net pondus armorum (kg) | 285 | 260 | 400 | 500 | 580 | 800 | 900 | 1600 | 2500 | 3000 | 2450 | 2950 | 3350 | 3960 |